Notifications
You must be signed in to change notification settings - Fork 221
Closed
Labels
status: waiting for informationMore information must be provided before work can proceedMore information must be provided before work can proceed
Description
It appears something is causing my Arduino Nano 33 BLE and Arduino Nao 33 BLE Sense to load repeated HCI_EVENT_PKT
bytes into _recvBuffer
. This is what the serial output looks like when using BLE.debug(Serial)
:
HCI EVENT RX <- 0404040404
3E
1B
Another example failure:
HCI EVENT RX <- 0404043E0C0201
HCI EVENT RX <- 0401B7DAD7FA625700C80404040404040404040404043E1E02010001B7DAD7FA62571202011A020A070BFF4C001006381E04B474BFCE043E0C02010401B7DAD7FA625700CE040404043E1D020100001BF99F3732501102011A020A0C0AFF4C0010050314109CE8BD04043E0C02010401A7AE7B27BD5000CD040404043E2B02010301D9201A4FC5331F1EFF060001092002DF763A72CF5951F1D056BB5486C5A6EE4DA5E21EE2AF5CAD04043E1D020100001BF99F373250110201
1A
After that, the Serial interface hangs and the main LED repeatedly flashes 4 long and 4 short.
I was able to hack this fix into void HCIClass::poll(unsigned long timeout)
:
while (HCITransport.available()) {
byte b = HCITransport.read();
//haxhaxhax for repeated start-event bytes
if (_recvIndex == 1 && _recvBuffer[0] == HCI_EVENT_PKT && b == HCI_EVENT_PKT) {
_recvIndex = 0;
}
//ENDhaxhaxhax
_recvBuffer[_recvIndex++] = b;
if (_recvBuffer[0] == HCI_ACLDATA_PKT) {
This works for my particular use case because I'm dealing only with advertisements, but it would break for anyone trying to make connections since it would blow up an HCI_Connection_Request
event.
If anyone has any guidance for what might be causing the HCI_EVENT_PKT
byte to be repeated, I can work on a real patch and pull-request.
Metadata
Metadata
Assignees
Labels
status: waiting for informationMore information must be provided before work can proceedMore information must be provided before work can proceed